NexLog DX-Series Recording Solutions
for P25 Trunked and Conventional Radio Systems

You are here

P25 Radio Recording and Interoperability

Eventide's engineers are industry experts for the recording of P25 radio systems, and more than 200 Eventide P25-integrated recorders have been sold. Eventide offers integration and interoperability with all of the following P25 radio systems:

Motorola Solutions - ASTRO 25
(Eventide Inc. is a licensed developer, and is a supplier of P25 recording systems to Motorola Solutions)

NexLog DX-Series communications recording solutions (and original NexLog recorders) support the recording of P25 trunked, P25 conventional, and analog conventional communications occurring on Motorola ASTRO 25 IP-infrastructure radio systems with MCC7500 consoles. The NexLog DX-Series recording Solution interoperates with the customer's Archive Interface Server (AIS) and Voice Processing Module (VPM) to capture, record, and archive the IP audio streams and call-related metadata for each voice transmission. The NexLog DX-Series integration to ASTRO 25 has been validated at the Motorola partner validation lab in Schaumburg IL. Eventide currently offers validated integration to ASTRO 25 system releases 7.11 through A2019.2.  More than 200 Eventide recorders with Astro 25/AIS integration have been sold.

Additional Information:
Eventide Application Note - Recording Solutions for ASTRO 25
Validation Certificate: Eventide and Motorola ASTRO 25 - System Release A2019.2

Motorola Solutions - SmartNet and SmartZone systems

NexLog DX-Series communications recording solutions also support recording of trunked and conventional calls on legacy Motorola SmartNet and SmartZone Analog trunked systems that are equipped with Genesis GenWatch (with GenSpout data output). Please contact Eventide for application review and a quotation for SmartNet/SmartZone Analog trunked system recording.

L3Harris Corporation - VIDA P25
(Eventide Inc. is a Harris-certified developer, and is a supplier of P25 recordering systems to L3Harris Corp.)

NexLog DX-Series communications recording solutions (and original NexLog recorders) support the recording of Group calls, Individual Calls, Emergency Calls, Patch calls, and ADPCM calls on the latest version of L3Harris VIDA P25 radio systems. The NexLog DX-Series recording solution interoperates with the customer's VNIC (and optional L3Harris KMF integration) to capture, record, and archive the IP audio streams and call-related metadata from each voice transmission.  Eventide Inc. is an L3Harris-Certified developer.  The Eventide integration to L3Harris VIDA P25 has been tested and validated at the L3Harris lab in Lynchburg VA, and applies to VIDA versions SR10A through SR10A5. The NexLog DX-Series integration with version SR10A2 and later can support the capture of GPS location data associated with P25 transmissions from GPS-equipped Harris P25 radios. The captured GPS coordinates are available for display on a map using Eventide MediaWorks DX software (map enabling license required).  More than 40 NexLog series recorders with L3Harris VIDA P25 integration have been sold.

Additional Information:
Eventide Application Note - Recording Solutions for L3Harris P25
Validation Letter - Eventide and L3Harris P25

EF Johnson Technologies - ATLAS P25
(Eventide Inc. is a supplier of P25 recording systems to EF Johnson Technologies)

NexLog DX-Series recording solutions (and original NexLog recorders) support the recording of Talk Group calls and Conventional calls on the EF Johnson ATLAS P25 radio system. The NexLog DX-Series recording solution interoperates with the ATLAS P25 radio system via network interface to capture, record, and archive the IP audio streams and call-related metadata from each voice transmission.

Additional Information:
Eventide Application Note - Recording Solutions for EF Johnson P25

Tait Communications - Tait P25 Trunked
(Eventide Inc. is a Tait Endorsed Partner and worldwide supplier of P25 and DMR recorder systems to Tait Communications)

NexLog DX-Series recording solutions support the recording of Talk Group calls on the Tait P25 trunked radio system. The NexLog DX-Series recording solution interoperates via ISSI to capture, record, and archive the IP audio streams and call-related metadata from each group voice transmission.  Eventide also offers Tait-certified integration to the Tait "EnableProtect" KMF for OTAR.

Additional Information:
Eventide Application Note - Recording Solutions for Tait Trunked P25 via ISSI 

APCO-Standard P25 Interfaces - ISSI and OTAR

ISSI: NexLog DX-Series recording solutions support the recording of Talk Group calls on P25 radio systems via the ISSI interface. The NexLog DX-Series recording solution interoperates with a P25 Trunked RF Sub-System (RFSS) via the APCO standard Inter-RF Sub-Sysem Interface (ISSI) to capture, record, and archive the IP audio streams and call-related metadata for designated talk groups.

OTAR: NexLog DX-Series communications recording solutions can be licensed for rekeying interoperability with an APCO-standard P25 Key Management Facility (KMF).  Eventide offers optional Tait-certified integration to the Tait "EnableProtect" KMF.

NEXLOG DX-Series Brochure